| Items |
Specification |
| Touch panel |
10.7”Color |
| Load |
Stack magazine x 2 (100pcs/magazine) |
| Unload |
1.Stack magazine x 2
2.May setup material by touch panel
3.May setup turn over material |
| Laser module |
1.KEYENCE MD-V9920W
2.Wave:1064 nm
3.Power: 13 W
4.Operating area: 300*300*42mm
|
| Vision alignment module |
2 mirror sets, support material alignment and adjust |
| Testing |
1.May setup golden units for OPEN /SHORT
2.NG units pick out and display automatically
3.May setup resistance reading of Open/Short test
|
| Material transport |
Transport units is vacuum installed for preventing 2 frames sticked |
| Material transport & alignment |
1.Area to area material transport by conveyor
2.Units be locked and vacuummed before Laser
3.Units be locked and vacuummed before Test
|
| Breakdown or Shutdown |
Monitor display location and error code |
| Software control |
1.OMRON PLC controlled machine movement 2.PC controlled Laser and CCD |
| Power off prevention |
UPS installed |